Unfortunately it's something different here. >>> Nikita Michalko <[email protected]> schrieb am 11.06.2013 um 15:29 >>> in Nachricht <[email protected]>: > Also seen in logs with the pacemaker 1.1.5: the point was unequal MTU > settings between the > servers ;-) > After setting the same MTU on both NICs, all was working like a charm! > > > Have a nice day! > > > Nikita Michalko > > > Am Mittwoch, 5. Juni 2013 14:25:19 schrieb Ulrich Windl: >> Hi! >> >> When the cluster (SLES11 SP2, current) was put in maintenance mode, two >> messages repeat periodically, filling the log: ERROR: crm_timer_popped: >> Election Timeout (I_ELECTION_DC) just popped in state S_RELEASE_DC! >> (120000ms) WARN: do_log: FSA: Input I_ELECTION_DC from crm_timer_popped() >> received in state S_RELEASE_DC >> >> crmd: [7285]: info: handle_request: Current ping state: S_RELEASE_DC >> >> Is this expected, or is it yet another bug (pacemaker-1.1.7-0.13.9)? >> >> Regards, >> Ulrich >> >> >> _______________________________________________ >> Linux-HA mailing list >> [email protected] >> http://lists.linux-ha.org/mailman/listinfo/linux-ha >> See also: http://linux-ha.org/ReportingProblems >> > _______________________________________________ > Linux-HA mailing list > [email protected] > http://lists.linux-ha.org/mailman/listinfo/linux-ha > See also: http://linux-ha.org/ReportingProblems
_______________________________________________ Linux-HA mailing list [email protected] http://lists.linux-ha.org/mailman/listinfo/linux-ha See also: http://linux-ha.org/ReportingProblems