Document new ABI attributes: {in,power,curr,temp}_samples and samples.

Signed-off-by: Krzysztof Adamski <[email protected]>
---
 Documentation/hwmon/sysfs-interface | 18 ++++++++++++++++++
 1 file changed, 18 insertions(+)

diff --git a/Documentation/hwmon/sysfs-interface 
b/Documentation/hwmon/sysfs-interface
index 2b9e1005d88b..7b91706d01c8 100644
--- a/Documentation/hwmon/sysfs-interface
+++ b/Documentation/hwmon/sysfs-interface
@@ -756,6 +756,24 @@ intrusion[0-*]_beep
                1: enable
                RW
 
+********************************
+* Average sample configuration *
+********************************
+
+Devices allowing for reading {in,power,curr,temp}_average values may export
+attributes for controlling number of samples used to compute average.
+
+samples                Sets number of average samples for all types of 
measurements.
+               RW
+
+in_samples
+power_samples
+curr_samples
+temp_samples    Sets number of average samples for specific type of 
measurements.
+               Note that on some devices it won't be possible to set all of 
them
+               to different values so changing one might also change some 
others.
+               RW
+
 
 sysfs attribute writes interpretation
 -------------------------------------
-- 
2.20.1

Reply via email to