Document new ABI attributes: {in,power,curr,temp}_samples and samples.
Signed-off-by: Krzysztof Adamski <[email protected]>
---
Documentation/hwmon/sysfs-interface | 18 ++++++++++++++++++
1 file changed, 18 insertions(+)
diff --git a/Documentation/hwmon/sysfs-interface
b/Documentation/hwmon/sysfs-interface
index 2b9e1005d88b..7b91706d01c8 100644
--- a/Documentation/hwmon/sysfs-interface
+++ b/Documentation/hwmon/sysfs-interface
@@ -756,6 +756,24 @@ intrusion[0-*]_beep
1: enable
RW
+********************************
+* Average sample configuration *
+********************************
+
+Devices allowing for reading {in,power,curr,temp}_average values may export
+attributes for controlling number of samples used to compute average.
+
+samples Sets number of average samples for all types of
measurements.
+ RW
+
+in_samples
+power_samples
+curr_samples
+temp_samples Sets number of average samples for specific type of
measurements.
+ Note that on some devices it won't be possible to set all of
them
+ to different values so changing one might also change some
others.
+ RW
+
sysfs attribute writes interpretation
-------------------------------------
--