Hi,

On Thu, Sep 08, 2016 at 07:10:00PM -0700, Guenter Roeck wrote:
> According to the Smart Battery Data Specification, the use
> of ManufacturerAcess (register 0x0) is implementation-defined.
> It appears that some batteries use writes to this register
> in order to implement certain functionality, but others may
> simply NAK all writes to it. As a result, write failures to
> ManufacturerAccess should not be used as an indicator of
> battery presence, nor as a failure to enter sleep mode.
> 
> The failed write access was seen with SANYO AP13J3K.
> 
> Cc: Brian Norris <briannor...@chromium.org>
> Signed-off-by: Guenter Roeck <li...@roeck-us.net>

Thanks, queued.

-- Sebastian

Attachment: signature.asc
Description: PGP signature

Reply via email to