> On Sat, 15 Oct 2016 12:37:55 +0000
> Bharat Kumar Gogada <bharat.kumar.gog...@xilinx.com> wrote:
> 
> Hi Bharat,
> 
> > Can anyone tell why MSI interrupts are limited to maximum 32
> > interrupts, even though we have 16bit message data register ?
> 
> That's the very definition of the original PCI MSI: Up to 32 consecutive 
> interrupts
> per function, and a single doorbell address.
> MSI-X lifts that restriction and offers up to 2048 interrupts that do not 
> have to
> be contiguous can target individual doorbells. Assuming your MSI controller
> advertises MSI-X support and that your devices do support it as well, you'll 
> be
> able to enjoy those.
> 

Thanks Marc, so then only 5 bits of message data register will be used, so what 
is the purpose rest of the bits ?

> >
> > Regards,
> > Bharat
> >
> >
> > This email and any attachments are intended for the sole use of the
> > named recipient(s) and contain(s) confidential information that may be
> > proprietary, privileged or copyrighted under applicable law. If you
> > are not the intended recipient, do not read, copy, or forward this
> > email message or any attachments. Delete this email message and any
> > attachments immediately.
> >
> 
> Please fix your email not to carry such disclaimer (or use a private email 
> address
> if you can't work around your company policy). Posting confidential 
> information
> on a public mailing list feels a bit silly.
> 
> Thanks,
> 
>       M.
> --
> Without deviation from the norm, progress is not possible.

Reply via email to