On Sun, Jan 22, 2017 at 01:23:07PM +0000, Jonathan Cameron wrote: >On 19/01/17 15:06, William Breathitt Gray wrote: >> The Apex Embedded Systems STX104 series provides a digital output >> register where 4 lines may be set at a time. This patch add support for >> the set_multiple callback function, thus allowing multiple digital >> output lines to be set more efficiently in groups. >> >> Cc: Jonathan Cameron <[email protected]> >> Cc: Hartmut Knaack <[email protected]> >> Cc: Lars-Peter Clausen <[email protected]> >> Cc: Peter Meerwald-Stadler <[email protected]> >> Signed-off-by: William Breathitt Gray <[email protected]> >Acked-by: Jonathan Cameron <[email protected]>
Jonathan Cameron, Would you pick this patch up in one of your iio.git branches? Thanks, William Breathitt Gray