On Thu, Aug 10, 2017 at 04:57:49PM -0500, eaja...@linux.vnet.ibm.com wrote:
> From: "Edward A. James" <eaja...@us.ibm.com>
> 
> Add PB_STATUS_INPUT as the generic alarm bit for iin and pin. We also
> need to redo the status register checking before setting up the boolean
> attribute, since it won't necessarily check STATUS_WORD if the device
> doesn't support it, which we need for this bit.
> 
> Signed-off-by: Edward A. James <eaja...@us.ibm.com>

Applied to hwmon-next.

Thanks,
Guenter

> ---
>  drivers/hwmon/pmbus/pmbus_core.c | 10 +++++++++-
>  1 file changed, 9 insertions(+), 1 deletion(-)
> 
> diff --git a/drivers/hwmon/pmbus/pmbus_core.c 
> b/drivers/hwmon/pmbus/pmbus_core.c
> index 277d170..ef135d8 100644
> --- a/drivers/hwmon/pmbus/pmbus_core.c
> +++ b/drivers/hwmon/pmbus/pmbus_core.c
> @@ -114,6 +114,7 @@ struct pmbus_data {
>        */
>       u16 status[PB_NUM_STATUS_REG];
>  
> +     bool has_status_word;           /* device uses STATUS_WORD register */
>       int (*read_status)(struct i2c_client *client, int page);
>  
>       u8 currpage;
> @@ -1045,6 +1046,7 @@ static int pmbus_add_sensor_attrs_one(struct i2c_client 
> *client,
>                                     const struct pmbus_sensor_attr *attr)
>  {
>       struct pmbus_sensor *base;
> +     bool upper = !!(attr->gbit & 0xff00);   /* need to check STATUS_WORD */
>       int ret;
>  
>       if (attr->label) {
> @@ -1065,9 +1067,11 @@ static int pmbus_add_sensor_attrs_one(struct 
> i2c_client *client,
>               /*
>                * Add generic alarm attribute only if there are no individual
>                * alarm attributes, if there is a global alarm bit, and if
> -              * the generic status register for this page is accessible.
> +              * the generic status register (word or byte, depending on
> +              * which global bit is set) for this page is accessible.
>                */
>               if (!ret && attr->gbit &&
> +                 (!upper || (upper && data->has_status_word)) &&
>                   pmbus_check_status_register(client, page)) {
>                       ret = pmbus_add_boolean(data, name, "alarm", index,
>                                               NULL, NULL,
> @@ -1324,6 +1328,7 @@ static int pmbus_add_sensor_attrs(struct i2c_client 
> *client,
>               .func = PMBUS_HAVE_IIN,
>               .sfunc = PMBUS_HAVE_STATUS_INPUT,
>               .sbase = PB_STATUS_INPUT_BASE,
> +             .gbit = PB_STATUS_INPUT,
>               .limit = iin_limit_attrs,
>               .nlimit = ARRAY_SIZE(iin_limit_attrs),
>       }, {
> @@ -1408,6 +1413,7 @@ static int pmbus_add_sensor_attrs(struct i2c_client 
> *client,
>               .func = PMBUS_HAVE_PIN,
>               .sfunc = PMBUS_HAVE_STATUS_INPUT,
>               .sbase = PB_STATUS_INPUT_BASE,
> +             .gbit = PB_STATUS_INPUT,
>               .limit = pin_limit_attrs,
>               .nlimit = ARRAY_SIZE(pin_limit_attrs),
>       }, {
> @@ -1775,6 +1781,8 @@ static int pmbus_init_common(struct i2c_client *client, 
> struct pmbus_data *data,
>                       dev_err(dev, "PMBus status register not found\n");
>                       return -ENODEV;
>               }
> +     } else {
> +             data->has_status_word = true;
>       }
>  
>       /* Enable PEC if the controller supports it */

Reply via email to