On 26/10/2017 at 14:17:30 +0200, SF Markus Elfring wrote:
> From: Markus Elfring <[email protected]>
> Date: Thu, 26 Oct 2017 14:06:49 +0200
> 
> * Add jump targets so that two error messages are stored only once
>   at the end of this function implementation.
> 
> * Adjust condition checks.
> 
> * Replace string literals by references to two global constant variables
>   in eight functions.
> 
> This issue was detected by using the Coccinelle software.
> 
> Signed-off-by: Markus Elfring <[email protected]>
> ---
>  drivers/iio/light/opt3001.c | 88 
> +++++++++++++++++++--------------------------
>  1 file changed, 36 insertions(+), 52 deletions(-)
> 
> diff --git a/drivers/iio/light/opt3001.c b/drivers/iio/light/opt3001.c
> index 54d88b60e303..23d7d4e6ae61 100644
> --- a/drivers/iio/light/opt3001.c
> +++ b/drivers/iio/light/opt3001.c
> @@ -77,6 +77,9 @@
>  #define OPT3001_RESULT_READY_SHORT   150
>  #define OPT3001_RESULT_READY_LONG    1000
>  
> +static char const read_failure[] = "failed to read register %02x\n";
> +static char const write_failure[] = "failed to write register %02x\n";
> +

If you are going to do that, why don't you use only one string: "failed
to %s register %02x\n"?


-- 
Alexandre Belloni, Free Electrons
Embedded Linux and Kernel engineering
http://free-electrons.com

Reply via email to