On Thu, Dec 07, 2017 at 05:20:02PM +0700, Arseny Solokha wrote:
> According to the reference manuals for the corresponding SoCs, SEC
> frequency ratio configuration is indicated by bit 26 of the POR Device
> Status Register 2. Consequently, SEC_CFG bit should be tested by mask 0x20,
> not 0x80. Testing the wrong bit leads to selection of wrong I2C clock
> prescaler on those SoCs.
> 
> Signed-off-by: Arseny Solokha <[email protected]>

Applied to for-next, thanks!