On 2018-02-02 04:32, Corey Minyard wrote:
+static void kcs_bmc_handle_cmd(struct kcs_bmc *kcs_bmc) +{ + u8 cmd; + + set_state(kcs_bmc, WRITE_STATE); + write_data(kcs_bmc, KCS_ZERO_DATA); + + cmd = read_data(kcs_bmc); + switch (cmd) { + case KCS_CMD_WRITE_START: + if (kcs_bmc->phase != KCS_PHASE_IDLE && + kcs_bmc->phase != KCS_PHASE_ERROR) { + kcs_force_abort(kcs_bmc); + break; + } +The spec says you can do a write start basically any time and the state machine starts over. I know I kind of went back and forth on this in my previous email, but what you had before is correct, I think.
So change it to the bellowing code is OK now? :-) + case KCS_CMD_WRITE_START: + kcs_bmc->data_in_avail = false; + kcs_bmc->data_in_idx = 0; + kcs_bmc->phase = KCS_PHASE_WRITE; + kcs_bmc->error = KCS_NO_ERROR; + break;
-corey