From: Colin Ian King <[email protected]>

[ Upstream commit c894acc7bf400d039bf740420b22f0b71b7fb504 ]

Ensure that when an invalid value in ret or value is found -EINVAL
is returned. A previous commit broke the way the return error is
being returned and instead caused the return code in ret to be
re-assigned rather than be returned.

Fixes: 5d9854eaea776 ("iio: hid-sensor: Store restore poll and hysteresis on 
S3")
Signed-off-by: Colin Ian King <[email protected]>
Signed-off-by: Jonathan Cameron <[email protected]>
Signed-off-by: Sasha Levin <[email protected]>
---
 drivers/iio/common/hid-sensors/hid-sensor-attributes.c | 4 ++--
 1 file changed, 2 insertions(+), 2 deletions(-)

diff --git a/drivers/iio/common/hid-sensors/hid-sensor-attributes.c 
b/drivers/iio/common/hid-sensors/hid-sensor-attributes.c
index ab646a90e3da..af85db50412e 100644
--- a/drivers/iio/common/hid-sensors/hid-sensor-attributes.c
+++ b/drivers/iio/common/hid-sensors/hid-sensor-attributes.c
@@ -215,7 +215,7 @@ int hid_sensor_write_samp_freq_value(struct 
hid_sensor_common *st,
        ret = sensor_hub_set_feature(st->hsdev, st->poll.report_id,
                                     st->poll.index, sizeof(value), &value);
        if (ret < 0 || value < 0)
-               ret = -EINVAL;
+               return -EINVAL;
 
        ret = sensor_hub_get_feature(st->hsdev,
                                     st->poll.report_id,
@@ -265,7 +265,7 @@ int hid_sensor_write_raw_hyst_value(struct 
hid_sensor_common *st,
                                     st->sensitivity.index, sizeof(value),
                                     &value);
        if (ret < 0 || value < 0)
-               ret = -EINVAL;
+               return -EINVAL;
 
        ret = sensor_hub_get_feature(st->hsdev,
                                     st->sensitivity.report_id,
-- 
2.14.1