Quoting Eddie James (2018-03-08 12:57:20) > According to the Aspeed specification, the reset and enable sequence > should be done when the clock is stopped. The specification doesn't > define behavior if the reset is done while the clock is enabled. > > From testing on the AST2500, the LPC Controller has problems if the > clock is reset while enabled. > > Therefore, check whether the clock is enabled or not before performing > the reset and enable sequence in the Aspeed clock driver. > > Root-caused-by: Lei Yu <mine260...@gmail.com> > Signed-off-by: Eddie James <eaja...@linux.vnet.ibm.com> > ---
Applied to clk-fixes