Hi Gustavo,

On Tue, Oct 09, 2018 at 09:38:33PM +0200, Gustavo A. R. Silva wrote:
> Currently, the error handling for the call to function
> phy_read_paged() doesn't work because *reg_val* is of
> type u16 (16 bits, unsigned), which makes it impossible
> for it to hold a value less than 0.
> 

Ah, rookie mistake! I should have run Coccinelle on the patches.

> Fix this by changing the type of variable *reg_val* to int.
> 
> Addresses-Coverity-ID: 1473970 ("Unsigned compared against 0")
> Fixes: 6a0bfbbe20b0 ("net: phy: mscc: migrate to phy_select/restore_page 
> functions")

Reviewed-by: Quentin Schulz <[email protected]>

Thanks!
Quentin

Attachment: signature.asc
Description: PGP signature

Reply via email to