From: Yuanjiang Yu <yuanjiang...@unisoc.com>

Our charger manager can optimize the battery capacity periodically, so
we can save last battery capacity into registers. Then next system
power-on, we can read the last saved battery capacity as the initial
battery capacity, which can make the battery capacity more accurate.

Signed-off-by: Yuanjiang Yu <yuanjiang...@unisoc.com>
Signed-off-by: Baolin Wang <baolin.w...@linaro.org>
---
 drivers/power/supply/sc27xx_fuel_gauge.c |  143 +++++++++++++++++++++++++++++-
 1 file changed, 142 insertions(+), 1 deletion(-)

diff --git a/drivers/power/supply/sc27xx_fuel_gauge.c 
b/drivers/power/supply/sc27xx_fuel_gauge.c
index 8c52e29..181a8f7 100644
--- a/drivers/power/supply/sc27xx_fuel_gauge.c
+++ b/drivers/power/supply/sc27xx_fuel_gauge.c
@@ -39,6 +39,9 @@
 #define SC27XX_FGU_CLBCNT_VALH         0x68
 #define SC27XX_FGU_CLBCNT_VALL         0x6c
 #define SC27XX_FGU_CLBCNT_QMAXL                0x74
+#define SC27XX_FGU_USER_AREA_SET       0xa0
+#define SC27XX_FGU_USER_AREA_CLEAR     0xa4
+#define SC27XX_FGU_USER_AREA_STATUS    0xa8
 
 #define SC27XX_WRITE_SELCLB_EN         BIT(0)
 #define SC27XX_FGU_CLBCNT_MASK         GENMASK(15, 0)
@@ -49,6 +52,14 @@
 #define SC27XX_FGU_LOW_OVERLOAD_INT    BIT(0)
 #define SC27XX_FGU_CLBCNT_DELTA_INT    BIT(2)
 
+#define SC27XX_FGU_MODE_AREA_MASK      GENMASK(15, 12)
+#define SC27XX_FGU_CAP_AREA_MASK       GENMASK(11, 0)
+#define SC27XX_FGU_MODE_AREA_SHIFT     12
+
+#define SC27XX_FGU_FIRST_POWERTON      GENMASK(3, 0)
+#define SC27XX_FGU_DEFAULT_CAP         GENMASK(11, 0)
+#define SC27XX_FGU_NORMAIL_POWERTON    0x5
+
 #define SC27XX_FGU_CUR_BASIC_ADC       8192
 #define SC27XX_FGU_SAMPLE_HZ           2
 
@@ -119,6 +130,80 @@ static int sc27xx_fgu_voltage_to_adc(struct 
sc27xx_fgu_data *data, int vol)
        return DIV_ROUND_CLOSEST(vol * data->vol_1000mv_adc, 1000);
 }
 
+static bool sc27xx_fgu_is_first_poweron(struct sc27xx_fgu_data *data)
+{
+       int ret, status, cap, mode;
+
+       ret = regmap_read(data->regmap,
+                         data->base + SC27XX_FGU_USER_AREA_STATUS, &status);
+       if (ret)
+               return false;
+
+       /*
+        * We use low 4 bits to save the last battery capacity and high 12 bits
+        * to save the system boot mode.
+        */
+       mode = (status & SC27XX_FGU_MODE_AREA_MASK) >> 
SC27XX_FGU_MODE_AREA_SHIFT;
+       cap = status & SC27XX_FGU_CAP_AREA_MASK;
+
+       /*
+        * When FGU has been powered down, the user area registers became
+        * default value (0xffff), which can be used to valid if the system is
+        * first power on or not.
+        */
+       if (mode == SC27XX_FGU_FIRST_POWERTON || cap == SC27XX_FGU_DEFAULT_CAP)
+               return true;
+
+       return false;
+}
+
+static int sc27xx_fgu_save_boot_mode(struct sc27xx_fgu_data *data,
+                                    int boot_mode)
+{
+       int ret;
+
+       ret = regmap_update_bits(data->regmap,
+                                data->base + SC27XX_FGU_USER_AREA_CLEAR,
+                                SC27XX_FGU_MODE_AREA_MASK,
+                                SC27XX_FGU_MODE_AREA_MASK);
+       if (ret)
+               return ret;
+
+       return regmap_update_bits(data->regmap,
+                                 data->base + SC27XX_FGU_USER_AREA_SET,
+                                 SC27XX_FGU_MODE_AREA_MASK,
+                                 boot_mode << SC27XX_FGU_MODE_AREA_SHIFT);
+}
+
+static int sc27xx_fgu_save_last_cap(struct sc27xx_fgu_data *data, int cap)
+{
+       int ret;
+
+       ret = regmap_update_bits(data->regmap,
+                                data->base + SC27XX_FGU_USER_AREA_CLEAR,
+                                SC27XX_FGU_CAP_AREA_MASK,
+                                SC27XX_FGU_CAP_AREA_MASK);
+       if (ret)
+               return ret;
+
+       return regmap_update_bits(data->regmap,
+                                 data->base + SC27XX_FGU_USER_AREA_SET,
+                                 SC27XX_FGU_CAP_AREA_MASK, cap);
+}
+
+static int sc27xx_fgu_read_last_cap(struct sc27xx_fgu_data *data, int *cap)
+{
+       int ret, value;
+
+       ret = regmap_read(data->regmap,
+                         data->base + SC27XX_FGU_USER_AREA_STATUS, &value);
+       if (ret)
+               return ret;
+
+       *cap = value & SC27XX_FGU_CAP_AREA_MASK;
+       return 0;
+}
+
 /*
  * When system boots on, we can not read battery capacity from coulomb
  * registers, since now the coulomb registers are invalid. So we should
@@ -128,6 +213,20 @@ static int sc27xx_fgu_voltage_to_adc(struct 
sc27xx_fgu_data *data, int vol)
 static int sc27xx_fgu_get_boot_capacity(struct sc27xx_fgu_data *data, int *cap)
 {
        int volt, cur, oci, ocv, ret;
+       bool is_first_poweron = sc27xx_fgu_is_first_poweron(data);
+
+       /*
+        * If system is not the first power on, we should use the last saved
+        * battery capacity as the initial battery capacity. Otherwise we should
+        * re-calculate the initial battery capacity.
+        */
+       if (!is_first_poweron) {
+               ret = sc27xx_fgu_read_last_cap(data, cap);
+               if (ret)
+                       return ret;
+
+               return sc27xx_fgu_save_boot_mode(data, 
SC27XX_FGU_NORMAIL_POWERTON);
+       }
 
        /*
         * After system booting on, the SC27XX_FGU_CLBCNT_QMAXL register saved
@@ -160,7 +259,11 @@ static int sc27xx_fgu_get_boot_capacity(struct 
sc27xx_fgu_data *data, int *cap)
        *cap = power_supply_ocv2cap_simple(data->cap_table, data->table_len,
                                           ocv);
 
-       return 0;
+       ret = sc27xx_fgu_save_last_cap(data, *cap);
+       if (ret)
+               return ret;
+
+       return sc27xx_fgu_save_boot_mode(data, SC27XX_FGU_NORMAIL_POWERTON);
 }
 
 static int sc27xx_fgu_set_clbcnt(struct sc27xx_fgu_data *data, int clbcnt)
@@ -418,6 +521,30 @@ static int sc27xx_fgu_get_property(struct power_supply 
*psy,
        return ret;
 }
 
+static int sc27xx_fgu_set_property(struct power_supply *psy,
+                                  enum power_supply_property psp,
+                                  const union power_supply_propval *val)
+{
+       struct sc27xx_fgu_data *data = power_supply_get_drvdata(psy);
+       int ret;
+
+       mutex_lock(&data->lock);
+
+       switch (psp) {
+       case POWER_SUPPLY_PROP_CAPACITY:
+               ret = sc27xx_fgu_save_last_cap(data, val->intval);
+               if (ret < 0)
+                       dev_err(data->dev, "failed to save battery capacity\n");
+               break;
+
+       default:
+               ret = -EINVAL;
+       }
+
+       mutex_unlock(&data->lock);
+       return ret;
+}
+
 static void sc27xx_fgu_external_power_changed(struct power_supply *psy)
 {
        struct sc27xx_fgu_data *data = power_supply_get_drvdata(psy);
@@ -425,6 +552,18 @@ static void sc27xx_fgu_external_power_changed(struct 
power_supply *psy)
        power_supply_changed(data->battery);
 }
 
+static int sc27xx_fgu_property_is_writeable(struct power_supply *psy,
+                                           enum power_supply_property psp)
+{
+       switch (psp) {
+       case POWER_SUPPLY_PROP_CAPACITY:
+               return 1;
+
+       default:
+               return 0;
+       }
+}
+
 static enum power_supply_property sc27xx_fgu_props[] = {
        POWER_SUPPLY_PROP_STATUS,
        POWER_SUPPLY_PROP_HEALTH,
@@ -444,7 +583,9 @@ static void sc27xx_fgu_external_power_changed(struct 
power_supply *psy)
        .properties             = sc27xx_fgu_props,
        .num_properties         = ARRAY_SIZE(sc27xx_fgu_props),
        .get_property           = sc27xx_fgu_get_property,
+       .set_property           = sc27xx_fgu_set_property,
        .external_power_changed = sc27xx_fgu_external_power_changed,
+       .property_is_writeable  = sc27xx_fgu_property_is_writeable,
 };
 
 static void sc27xx_fgu_adjust_cap(struct sc27xx_fgu_data *data, int cap)
-- 
1.7.9.5

Reply via email to