The thermal driver is a standalone driver for monitoring SoC temperature
by enabling thermal sensor, so it can be enabled even when CONFIG_CPU_FREQ
is NOT set. So remove the dependency with CPU_THERMAL.

Introduce dummy function of legacy cooling register/unregister to make
thermal driver probe successfully when CONFIG_CPU_FREQ is NOT set.

Signed-off-by: Anson Huang <anson.hu...@nxp.com>
---
changes since V3:
        rename the label of "cpufreq_put" with "legacy_cleanup".
 drivers/thermal/Kconfig       |  2 +-
 drivers/thermal/imx_thermal.c | 44 +++++++++++++++++++++++++++++++------------
 2 files changed, 33 insertions(+), 13 deletions(-)

diff --git a/drivers/thermal/Kconfig b/drivers/thermal/Kconfig
index 5422523..93bd3bb 100644
--- a/drivers/thermal/Kconfig
+++ b/drivers/thermal/Kconfig
@@ -212,7 +212,7 @@ config HISI_THERMAL
 
 config IMX_THERMAL
        tristate "Temperature sensor driver for Freescale i.MX SoCs"
-       depends on (ARCH_MXC && CPU_THERMAL) || COMPILE_TEST
+       depends on ARCH_MXC || COMPILE_TEST
        depends on NVMEM || !NVMEM
        depends on MFD_SYSCON
        depends on OF
diff --git a/drivers/thermal/imx_thermal.c b/drivers/thermal/imx_thermal.c
index 1566154..328ee05 100644
--- a/drivers/thermal/imx_thermal.c
+++ b/drivers/thermal/imx_thermal.c
@@ -648,15 +648,24 @@ static const struct of_device_id of_imx_thermal_match[] = 
{
 };
 MODULE_DEVICE_TABLE(of, of_imx_thermal_match);
 
+#ifdef CONFIG_CPU_FREQ
 /*
  * Create cooling device in case no #cooling-cells property is available in
  * CPU node
  */
 static int imx_thermal_register_legacy_cooling(struct imx_thermal_data *data)
 {
-       struct device_node *np = of_get_cpu_node(data->policy->cpu, NULL);
+       struct device_node *np;
        int ret;
 
+       data->policy = cpufreq_cpu_get(0);
+       if (!data->policy) {
+               pr_debug("%s: CPUFreq policy not found\n", __func__);
+               return -EPROBE_DEFER;
+       }
+
+       np = of_get_cpu_node(data->policy->cpu, NULL);
+
        if (!np || !of_find_property(np, "#cooling-cells", NULL)) {
                data->cdev = cpufreq_cooling_register(data->policy);
                if (IS_ERR(data->cdev)) {
@@ -669,6 +678,22 @@ static int imx_thermal_register_legacy_cooling(struct 
imx_thermal_data *data)
        return 0;
 }
 
+static void imx_thermal_unregister_legacy_cooling(struct imx_thermal_data 
*data)
+{
+       cpufreq_cooling_unregister(data->cdev);
+       cpufreq_cpu_put(data->policy);
+}
+#else
+static inline int imx_thermal_register_legacy_cooling(struct imx_thermal_data 
*data)
+{
+       return 0;
+}
+
+static inline void imx_thermal_unregister_legacy_cooling(struct 
imx_thermal_data *data)
+{
+}
+#endif
+
 static int imx_thermal_probe(struct platform_device *pdev)
 {
        struct imx_thermal_data *data;
@@ -743,13 +768,9 @@ static int imx_thermal_probe(struct platform_device *pdev)
        regmap_write(map, data->socdata->sensor_ctrl + REG_SET,
                     data->socdata->power_down_mask);
 
-       data->policy = cpufreq_cpu_get(0);
-       if (!data->policy) {
-               pr_debug("%s: CPUFreq policy not found\n", __func__);
-               return -EPROBE_DEFER;
-       }
-
        ret = imx_thermal_register_legacy_cooling(data);
+       if (ret == -EPROBE_DEFER)
+               return ret;
        if (ret) {
                dev_err(&pdev->dev,
                        "failed to register cpufreq cooling device: %d\n", ret);
@@ -762,7 +783,7 @@ static int imx_thermal_probe(struct platform_device *pdev)
                if (ret != -EPROBE_DEFER)
                        dev_err(&pdev->dev,
                                "failed to get thermal clk: %d\n", ret);
-               goto cpufreq_put;
+               goto legacy_cleanup;
        }
 
        /*
@@ -775,7 +796,7 @@ static int imx_thermal_probe(struct platform_device *pdev)
        ret = clk_prepare_enable(data->thermal_clk);
        if (ret) {
                dev_err(&pdev->dev, "failed to enable thermal clk: %d\n", ret);
-               goto cpufreq_put;
+               goto legacy_cleanup;
        }
 
        data->tz = thermal_zone_device_register("imx_thermal_zone",
@@ -829,9 +850,8 @@ static int imx_thermal_probe(struct platform_device *pdev)
        thermal_zone_device_unregister(data->tz);
 clk_disable:
        clk_disable_unprepare(data->thermal_clk);
-cpufreq_put:
-       cpufreq_cooling_unregister(data->cdev);
-       cpufreq_cpu_put(data->policy);
+legacy_cleanup:
+       imx_thermal_unregister_legacy_cooling(data);
 
        return ret;
 }
-- 
2.7.4

Reply via email to