Slightly better readability by setting fixed_uV instead of min_uV.

Signed-off-by: Axel Lin <axel....@ingics.com>
---
 drivers/regulator/ab3100.c | 7 +++----
 1 file changed, 3 insertions(+), 4 deletions(-)

diff --git a/drivers/regulator/ab3100.c b/drivers/regulator/ab3100.c
index edde907a7062..438509f55f05 100644
--- a/drivers/regulator/ab3100.c
+++ b/drivers/regulator/ab3100.c
@@ -354,7 +354,6 @@ static int ab3100_get_voltage_regulator_external(struct 
regulator_dev *reg)
 }
 
 static const struct regulator_ops regulator_ops_fixed = {
-       .list_voltage = regulator_list_voltage_linear,
        .enable      = ab3100_enable_regulator,
        .disable     = ab3100_disable_regulator,
        .is_enabled  = ab3100_is_enabled_regulator,
@@ -401,7 +400,7 @@ ab3100_regulator_desc[AB3100_NUM_REGULATORS] = {
                .n_voltages = 1,
                .type = REGULATOR_VOLTAGE,
                .owner = THIS_MODULE,
-               .min_uV = LDO_A_VOLTAGE,
+               .fixed_uV = LDO_A_VOLTAGE,
                .enable_time = 200,
        },
        {
@@ -411,7 +410,7 @@ ab3100_regulator_desc[AB3100_NUM_REGULATORS] = {
                .n_voltages = 1,
                .type = REGULATOR_VOLTAGE,
                .owner = THIS_MODULE,
-               .min_uV = LDO_C_VOLTAGE,
+               .fixed_uV = LDO_C_VOLTAGE,
                .enable_time = 200,
        },
        {
@@ -421,7 +420,7 @@ ab3100_regulator_desc[AB3100_NUM_REGULATORS] = {
                .n_voltages = 1,
                .type = REGULATOR_VOLTAGE,
                .owner = THIS_MODULE,
-               .min_uV = LDO_D_VOLTAGE,
+               .fixed_uV = LDO_D_VOLTAGE,
                .enable_time = 200,
        },
        {
-- 
2.20.1

Reply via email to