Currently, the driver sets the FIFO_SAMPLES register with the number of
sample sets (maximum of 170 for 3 axis data, 256 for 2-axis and 512 for
single axis). However, the FIFO_SAMPLES register should store the number
of samples, regardless of how the FIFO format is configured.

Signed-off-by: Stefan Popa <[email protected]>
---
 drivers/iio/accel/adxl372.c | 9 ---------
 1 file changed, 9 deletions(-)

diff --git a/drivers/iio/accel/adxl372.c b/drivers/iio/accel/adxl372.c
index 055227cb..adec37b 100644
--- a/drivers/iio/accel/adxl372.c
+++ b/drivers/iio/accel/adxl372.c
@@ -805,15 +805,6 @@ static int adxl372_buffer_postenable(struct iio_dev 
*indio_dev)
        st->fifo_format = adxl372_axis_lookup_table[i].fifo_format;
        st->fifo_set_size = bitmap_weight(indio_dev->active_scan_mask,
                                          indio_dev->masklength);
-       /*
-        * The 512 FIFO samples can be allotted in several ways, such as:
-        * 170 sample sets of concurrent 3-axis data
-        * 256 sample sets of concurrent 2-axis data (user selectable)
-        * 512 sample sets of single-axis data
-        */
-       if ((st->watermark * st->fifo_set_size) > ADXL372_FIFO_SIZE)
-               st->watermark = (ADXL372_FIFO_SIZE  / st->fifo_set_size);
-
        st->fifo_mode = ADXL372_FIFO_STREAMED;
 
        ret = adxl372_configure_fifo(st);
-- 
2.7.4