On 8/28/20 6:06 AM, Andre Przywara wrote:
> The SP805 DT binding requires two clocks to be specified, but the
> Broadcom Cygnus DT currently only specifies one clock.
> 
> In practice, Linux would pick a clock named "apb_pclk" for the bus
> clock, and the Linux and U-Boot SP805 driver would use the first clock
> to derive the actual watchdog counter frequency.
> 
> Since currently both are the very same clock, we can just double the
> clock reference, and add the correct clock-names, to match the binding.
> 
> Signed-off-by: Andre Przywara <andre.przyw...@arm.com>

Acked-by: Florian Fainelli <f.faine...@gmail.com>
-- 
Florian