Hello,

just a bit of nitpicking left. If Lee is going to apply, I can care for
a followup patch if need be.

On Mon, Sep 07, 2020 at 11:37:55PM +0200, Michael Walle wrote:
> [..]
> +config PWM_SL28CPLD
> +     tristate "Kontron sl28cpld PWM support"
> +     depends on MFD_SL28CPLD ||  COMPILE_TEST

s/  / / (@Lee, maybe fixup during application?)

> +     help
> +       Generic PWM framework driver for board management controller
> +       found on the Kontron sl28 CPLD.
> [...]
> +#define SL28CPLD_PWM_CLK                     32000 /* 32 kHz */
> +#define SL28CPLD_PWM_MAX_DUTY_CYCLE(prescaler)       (1 << (7 - (prescaler)))
> +#define SL28CPLD_PWM_PERIOD(prescaler) \
> +     (NSEC_PER_SEC / SL28CPLD_PWM_CLK * 
> SL28CPLD_PWM_MAX_DUTY_CYCLE(prescaler))
> +
> +/*
> + * We calculate the duty cycle like this:
> + *   duty_cycle_ns = pwm_cycle_reg * max_period_ns / max_duty_cycle
> + *
> + * With
> + *   max_period_ns = 1 << (7 - prescaler) / pwm_clk * NSEC_PER_SEC
> + *   max_duty_cycle = 1 << (7 - prescaler)
> + * this then simplifies to:
> + *   duty_cycle_ns = pwm_cycle_reg / pwm_clk * NSEC_PER_SEC
> + *
> + * NSEC_PER_SEC is a multiple of SL28CPLD_PWM_CLK, therefore we're not losing
> + * precision by doing the divison first.

The division you're talking about is NSEC_PER_SEC / pwm_clk which isn't
obvious in the formula in the line above. Maybe:

        ...
        this then simplifies to:

          duty_cycle_ns = NSEC_PER_SEC / SL28CPLD_PWM_CLK * pwm_cycle_reg

        NSEC_PER_SEC is a multiple of SL28CPLD_PWM_CLK, therefor ...

to make it easier to understand the comment.

> + */
> +#define SL28CPLD_PWM_TO_DUTY_CYCLE(reg) \
> +     (NSEC_PER_SEC / SL28CPLD_PWM_CLK * (reg))
> +#define SL28CPLD_PWM_FROM_DUTY_CYCLE(duty_cycle) \
> +     (DIV_ROUND_DOWN_ULL((duty_cycle), NSEC_PER_SEC / SL28CPLD_PWM_CLK))
> [...]
> +     /*
> +      * To avoid glitches when we switch the prescaler, we have to make sure
> +      * we have a valid duty cycle for the new mode.
> +      *
> +      * Take the current prescaler (or the current period length) into
> +      * account to decide whether we have to write the duty cycle or the new
> +      * prescaler first. If the period length is decreasing we have to
> +      * write the duty cycle first.
> +      */
> +     write_duty_cycle_first = pwm->state.period > state->period;
> +
> +     if (write_duty_cycle_first) {
> +             ret = sl28cpld_pwm_write(priv, SL28CPLD_PWM_CYCLE, cycle);
> +             if (ret)
> +                     return ret;
> +     }
> +
> +     ret = sl28cpld_pwm_write(priv, SL28CPLD_PWM_CTRL, ctrl);
> +     if (ret)
> +             return ret;
> +
> +     if (!write_duty_cycle_first) {
> +             ret = sl28cpld_pwm_write(priv, SL28CPLD_PWM_CYCLE, cycle);
> +             if (ret)
> +                     return ret;
> +     }

Nice! I didn't spend the necessary brain cycles to confirm this
algorithm, but it seems you did :-)

> +
> +     return 0;
> +}
> [...]

Best regards
Uwe

-- 
Pengutronix e.K.                           | Uwe Kleine-König            |
Industrial Linux Solutions                 | https://www.pengutronix.de/ |

Attachment: signature.asc
Description: PGP signature

Reply via email to