Hi, On 2020-01-16 11:41:34 -0800, Srinivas Pandruvada wrote: > On Thu, 2020-01-16 at 10:42 -0800, Andres Freund wrote: > > Hi, > > > > On 2020-01-16 05:53:13 -0800, Srinivas Pandruvada wrote: > > > On Wed, 2020-01-15 at 10:44 -0800, Andres Freund wrote: > > > > I noticed that I couldn't read the PCH temperature on my > > > > workstation > > > > (C620 series chipset, w/ 2x Xeon Gold 5215 CPUs) directly, but > > > > had to > > > > go > > > > through IPMI. Looking at the data sheet, it looks to me like the > > > > existing intel PCH thermal driver should work without changes for > > > > Lewisburg. > > > Does the temperature reading match with what you read via IPMI? > > > > It does: > > > > root@awork3:~# ipmitool sdr|grep ^PCH > > PCH Temp | 58 degrees C | ok > > > > andres@awork3:~$ cat /sys/class/thermal/thermal_zone0/type > > pch_lewisburg > > andres@awork3:~$ cat /sys/class/thermal/thermal_zone0/temp > > 58000 > > > > And if I generate some load, it rises for both: > > root@awork3:~# ipmitool sdr|grep ^PCH > > PCH Temp | 60 degrees C | ok > > andres@awork3:~$ cat /sys/class/thermal/thermal_zone0/temp > > 60000 > > > Thanks for the test. > > Rui can add his ACK.
Ping? Looks like this got lost somewhere? Greetings, Andres Freund