On Wed, 2020-12-09 at 15:09 -0800, Dmitry Torokhov wrote:
> Instead of using special-casing retrieval of number of X/Y electrodes
> based on the firmware, let's select default values and mark registers
> as
> non-existent on firmwares that do not support this operation.
> 
> Also mark "report rate" register as non-existent for generic
> firmwares as
> having it set to 0 does not make sense.

Looks good.

Reviewed-by: Simon Budig <simon.bu...@kernelconcepts.de>

Thanks,
        Simon
-- 
     kernel concepts GmbH                 Simon Budig
     Hauptstraße 16                       simon.bu...@kernelconcepts.de
     D-57076 Siegen                       +49-271-771091-17
     http://www.kernelconcepts.de/
     HR Siegen, HR B 9613; Geschäftsführer: Ole Reinhardt

Attachment: signature.asc
Description: This is a digitally signed message part

Reply via email to