On 8/24/2026 7:47 PM, Konrad Dybcio wrote:
On 8/9/26 2:29 PM, Gaurav Kohli wrote:
Unlike the CPU, the CDSP does not throttle its speed automatically
when it reaches high temperatures in talos.

[...]

+                       cooling-maps {
+                               map0 {
+                                       trip = <&q6_hvx_alert0>;
+                                       cooling-device = <&remoteproc_cdsp 
QCOM_TMD_CDSP_SW
+                                                        THERMAL_NO_LIMIT 
THERMAL_NO_LIMIT>;
+                               };
+                       };
                };
mdm-core-thermal {

Should this sensor also be bound to the rproc?

Thanks for the review, Konrad.

Talos does not have a modem remoteproc device defined in the DTS, looks
like modem support is not present/disable for this target.


Konrad


Reply via email to