"ext Tony Lindgren" <[EMAIL PROTECTED]> writes:

> * Igor Stoppa <[EMAIL PROTECTED]> [081014 14:12]:
>> On Tue, 2008-10-14 at 13:59 -0700, ext Tony Lindgren wrote:
>> 
>> > And that we can use same naming in the driver no matter which omap :)
>> 
>> Wasn't that one of the main features of the clock FW, when it was
>> designed?
>
> Yes. But we adding separate ick and fck during omap2420 confused
> that.

Why this was originally done? I mean we have possibility to autogate
interface clocks. AFAIK those could be just fine be enabled on boot and let
the hw to take care of them.

-- 
Jouni Högander

--
To unsubscribe from this list: send the line "unsubscribe linux-omap" in
the body of a message to [EMAIL PROTECTED]
More majordomo info at  http://vger.kernel.org/majordomo-info.html