It's flagged as degraded due to the driver version. OMSA has done this for awhile now. Driver Version : 01.101.06.00 Minimum Required Driver Version : 02.00.00.00
On Mon, Jul 26, 2010 at 11:34 AM, Gianluca Cecchi <[email protected] > wrote: > hello, > a blade M910 with RH EL 5.5 x86_64 and 6.2 agents. > Installed these: > libsmbios-2.2.19-10.1.el5.i386.rpm > libsmbios-2.2.19-10.1.el5.x86_64.rpm > RPM-GPG-KEY-dell > RPM-GPG-KEY-libsmbios > smbios-utils-bin-2.2.19-10.1.el5.x86_64.rpm > srvadmin-cm-6.2.0-677.i386.rpm > srvadmin-deng-6.2.0-1.6.el5.i386.rpm > srvadmin-fsa-6.2.0-1.6.el3.i386.rpm > srvadmin-hapi-6.2.0-1.17.el5.i386.rpm > srvadmin-isvc-6.2.0-1.16.el5.i386.rpm > srvadmin-megalib-6.2.0-1.6.el3.i386.rpm > srvadmin-omacore-6.2.0-1.18.el5.i386.rpm > srvadmin-omcommon-6.2.0-1.19.el5.i386.rpm > srvadmin-omilcore-6.2.0-1.9.el5.noarch.rpm > srvadmin-smcommon-6.2.0-1.29.el5.i386.rpm > srvadmin-storage-6.2.0-1.29.el5.i386.rpm > srvadmin-storage-populator-6.2.0-1.25.el3.i386.rpm > srvadmin-storelib-6.2.0-1.11.el3.i386.rpm > srvadmin-storelib-libpci-6.2.0-1.1.el5.i386.rpm > srvadmin-storelib-sysfs-6.2.0-1.1.el5.i386.rpm > srvadmin-sysfsutils-6.2.0-2.1.el5.i386.rpm > srvadmin-xmlsup-6.2.0-1.17.el5.i386.rpm > > I have this strange output when querying the controller status; state is > degraded, but OK... > > # omreport storage controller > Controller PERC H200 Integrated Modular (Embedded) > > Controllers > ID : 0 > Status : Non-Critical > Name : PERC H200 Integrated > Modular > Slot ID : Embedded > State : Degraded > Firmware Version : 07.01.33.00 > Minimum Required Firmware Version : Not Applicable > Driver Version : 01.101.06.00 > Minimum Required Driver Version : 02.00.00.00 > Storport Driver Version : Not Applicable > Minimum Required Storport Driver Version : Not Applicable > Number of Connectors : 1 > Rebuild Rate : 50% > BGI Rate : 50% > Check Consistency Rate : 50% > Reconstruct Rate : Not Applicable > Alarm State : Not Applicable > Cluster Mode : Not Applicable > SCSI Initiator ID : Not Applicable > Cache Memory Size : Not Applicable > Patrol Read Mode : Not Applicable > Patrol Read State : Not Applicable > Patrol Read Rate : Not Applicable > Patrol Read Iterations : Not Applicable > Abort check consistency on error : Not Applicable > Allow Revertible Hot Spare and Replace Member : Not Applicable > Auto replace member on predictive failure : Not Applicable > Load balance : Not Applicable > Security Capable : Not Applicable > Security Key Present : Not Applicable > Redundant Path view : Not Applicable > > using check_openmanage from > http://folk.uio.no/trondham/software/check_openmanage.html > with these options > > /usr/lib64/nagios/plugins/check_openmanage -o 0 --blacklist > ctrl_driver=0/ctrl_stdr=0 -d > > System: PowerEdge M910 > ServiceTag: OMSA version: 6.2.0 > BIOS/date: 1.1.7 05/25/2010 Plugin version: 3.5.10 > > ----------------------------------------------------------------------------- > Storage > Components > > ============================================================================= > STATE | ID | MESSAGE > TEXT > > ---------+----------+-------------------------------------------------------- > OK | 0 | Controller 0 [PERC H200 Integrated Modular] is > Degraded > OK | 0:0:0:0 | Physical Disk 0:0:0 [SAS-HDD 146GB] on ctrl 0 is > Online > OK | 0:0:0:1 | Physical Disk 0:0:1 [SAS-HDD 146GB] on ctrl 0 is > Online > OK | 0:0 | Logical Drive '/dev/sda' [RAID-1, 136.13 GB] is Ready > OK | 0:0 | Connector 0 [SAS Port RAID Mode] on controller 0 is > Ready > OK | 0:0:0 | Enclosure 0:0:0 [Backplane] on controller 0 is Ready > > ----------------------------------------------------------------------------- > > .... > > In general the standard check (without -d but with the blacklist option, as > the driver release in RH EL 5 is a little behind the reccomended..) returns > ok. > > So the question is > is it ok or not? > Entering directly into BIOS for the controller (Ctrl-C) gives Optimal as > state.... > > Is this a bug related with the text output....? > Thanks, > Gianluca > > > > _______________________________________________ > Linux-PowerEdge mailing list > [email protected] > https://lists.us.dell.com/mailman/listinfo/linux-poweredge > Please read the FAQ at http://lists.us.dell.com/faq >
_______________________________________________ Linux-PowerEdge mailing list [email protected] https://lists.us.dell.com/mailman/listinfo/linux-poweredge Please read the FAQ at http://lists.us.dell.com/faq