[email protected] wrote: > 1)The following link(Dell OM users guide) will help you to understand > the considerations for hot spare. > http://support.dell.com/support/edocs/software/svradmin/6.2/en/OMSS/hots > pr.htm#wp206346 > 2)The following link explains the OM CLI syntax to assign a dedicated > host spare to a vdisk(check "omconfig Assign Dedicated Hot Spare" > section) > http://support.dell.com/support/edocs/software/svradmin/6.2/en/CLI/HTML/ > storage.htm#wp1091778 > > Thanks, > Mohan
Hi Mohan, Thanks for the links, I'm afraid we're running 6.1 here, I never managed to get 6.2 to work. I got as far as supporting all the ipmi checks but couldn't get it to find the perc storage controllers. I followed all the guides on here about installing extra dependencies too. I might try allocating it as a global hot spare then, although some of the arrays have drives larger than it's capacity. sudo omconfig storage pdisk action=assigndedicatedhotspare controller=1 vdisk=0 pdisk=1:0:1 assign=yes Password: Error! Unrecognized parameter value: action=<blink|unblink|remove|initialize|rebuild|cancelrebuild|cancelreplacemember|offline|removedeadsegments|online|assignglobalhotspare|clear|cancelclear> g. _______________________________________________ Linux-PowerEdge mailing list [email protected] https://lists.us.dell.com/mailman/listinfo/linux-poweredge Please read the FAQ at http://lists.us.dell.com/faq