[email protected] wrote: > OM6.1 should be fine for hot spare assignment. > > There is a small error in the command that you tried. > If you are planning to assign pdisk1:0:1 as a dedicated hotspare to > vdisk0 try the below command. > > omconfig storage vdisk action=assigndedicatedhotspare controller=1 > vdisk=0 pdisk=1:0:1 assign=yes > > Thanks, > Mohan
Ah ha thanks Mohan that worked perfectly. ID : 1:0:1 Status : Ok Name : Physical Disk 1:0:1 State : Ready Failure Predicted : No Progress : Not Applicable Bus Protocol : SATA Media : HDD Capacity : 698.13 GB (749606010880 bytes) Used RAID Disk Space : 698.13 GB (749606010880 bytes) Available RAID Disk Space : 0.00 GB (0 bytes) Hot Spare : Dedicated Vendor ID : DELL Product ID : ST3750640NS Revision : 3BKH3BKH Serial No. : 5QD14NLV 5QD14NLV Negotiated Speed : Not Available Capable Speed : Not Available Manufacture Day : Not Available Manufacture Week : Not Available Manufacture Year : Not Available SAS Address : 500188B23C8C2587 g. _______________________________________________ Linux-PowerEdge mailing list [email protected] https://lists.us.dell.com/mailman/listinfo/linux-poweredge Please read the FAQ at http://lists.us.dell.com/faq