[email protected] wrote:
> OM6.1 should be fine for hot spare assignment.
> 
> There is a small error in the command that you tried.
> If you are planning to assign pdisk1:0:1 as a dedicated hotspare to
> vdisk0 try the below command.
> 
> omconfig storage vdisk action=assigndedicatedhotspare controller=1
> vdisk=0 pdisk=1:0:1 assign=yes
> 
> Thanks,
> Mohan

Ah ha thanks Mohan that worked perfectly.

ID                        : 1:0:1
Status                    : Ok
Name                      : Physical Disk 1:0:1
State                     : Ready
Failure Predicted         : No
Progress                  : Not Applicable
Bus Protocol              : SATA
Media                     : HDD
Capacity                  : 698.13 GB (749606010880 bytes)
Used RAID Disk Space      : 698.13 GB (749606010880 bytes)
Available RAID Disk Space : 0.00 GB (0 bytes)
Hot Spare                 : Dedicated
Vendor ID                 : DELL
Product ID                : ST3750640NS
Revision                  : 3BKH3BKH
Serial No.                : 5QD14NLV    5QD14NLV
Negotiated Speed          : Not Available
Capable Speed             : Not Available
Manufacture Day           : Not Available
Manufacture Week          : Not Available
Manufacture Year          : Not Available
SAS Address               : 500188B23C8C2587