2010/7/29 J. Epperson <[email protected]>: > On Thu, July 29, 2010 10:25, Nick Solin wrote: >> Yes, but no matter what I have done the OSMA does not work on my computer. >> I've read most of the OSMA documents and they tell you how to install and >> use the OSMA but they skip any sort of configuration for the OSMA. For >> instance when I try to use omreport: > [snip] >> >> The ones I need most are fans and temps. I've read through a few of the >> letters in the archives pertaining to the 1435SC, but none have helped. >> > > Other than the fact that it's OMSA, not OSMA, your original subject line > was correct: OMSA does not work on PowerEdge 1435SC.
omsa 6.2 may not support SC1435 but 5.5 works on PE SC1435 fine #omreport chassis info Chassis Information Index : 0 Chassis Name : Main System Chassis Host Name : BMC Version : 1.78 Chassis Model : PowerEdge SC1435 Chassis Lock : Present Chassis Service Tag : XXXXXXX Chassis Asset Tag : Flash chassis identify LED state : Off Flash chassis identify LED timeout value : 300 -- Lazy _______________________________________________ Linux-PowerEdge mailing list [email protected] https://lists.us.dell.com/mailman/listinfo/linux-poweredge Please read the FAQ at http://lists.us.dell.com/faq