2010/8/1 J. Epperson <[email protected]>: > On Sat, July 31, 2010 15:05, Lazy wrote: >> >> omsa 6.2 may not support SC1435 but 5.5 works on PE SC1435 fine >> >> #omreport chassis info >> Chassis Information >> >> Index : 0 >> Chassis Name : Main System Chassis >> Host Name : >> BMC Version : 1.78 >> Chassis Model : PowerEdge SC1435 >> Chassis Lock : Present >> Chassis Service Tag : XXXXXXX >> Chassis Asset Tag : >> Flash chassis identify LED state : Off >> Flash chassis identify LED timeout value : 300 >> >> -- > > Interesting. How did you install it? IIRC, 5.5.0 was what was shipped > with my old 1435SC servers, and reported "not a supported server" when you > tried to install it. Same thing happened if you downloaded 5.5.1 and > tried with that. Dell support was adamant at the time that the 1435SC was > not supported in spite of having shipped OMSA with it.
in fact this is 5.4.0 but on other machines I think we have 5.5 running, I'm using debian packages from sara.nl, before instaling omsa you have to make sure ipmit is working, without this sensors ect. won't work, enabling ipmi later won't help (omsa sets it's own ipmi config during install, so reinstall wont help if it was installed on a system without working ipmi, you have to remove and install omsa again) If You want only to monitor sensors, not configure anything ipmitool might be simpler then omsa (ipmitool sel list, ipmitool sdr required modules ipmi_si, ipmi_devintf) -- Lazy _______________________________________________ Linux-PowerEdge mailing list [email protected] https://lists.us.dell.com/mailman/listinfo/linux-poweredge Please read the FAQ at http://lists.us.dell.com/faq