Hi Nunio These are the minimum required Ubuntu packages to make use of OMSA command line interface (includes Storage related commands as well) alone. srvadmin-deng srvadmin-hapi srvadmin-isvc srvadmin-nvme srvadmin-omacore srvadmin-omacs srvadmin-omcommon srvadmin-omilcore srvadmin-ominst srvadmin-smcommon srvadmin-storage srvadmin-storage-cli srvadmin-storelib srvadmin-storelib-sysfs srvadmin-xmlsup
After installation of the above packages, please start the Data manager service using the below command. service dataeng start Regards Chandra ---------------------------------------------------------------------- Message: 1 Date: Mon, 16 May 2016 14:16:18 -0400 From: Nunio Besnes Subject: [Linux-PowerEdge] Ubuntu - Minimum OMSA install with omreport To: [email protected] Message-ID: Content-Type: text/plain; charset="utf-8" I've got a mix of servers some ubuntu 12.04, some 14.04. I'd like to use "omreport system alertlog" in a cron script to check hardware status and act upon hardware alerts (disk failure, overheating, power issues, etc.). I do not need a web interface and don't have the idrac configured. I've installed srvadmin-all and it works, but I'd rather not have stuff installed that I don't need. What would be the minimum I need to install for my purposes? Nunio -------------- next part -------------- An HTML attachment was scrubbed... URL: http://lists.us.dell.com/pipermail/linux-poweredge/attachments/20160516/583f7b14/attachment-0001.html ------------------------------ _______________________________________________ Linux-PowerEdge mailing list [email protected] https://lists.us.dell.com/mailman/listinfo/linux-poweredge End of Linux-PowerEdge Digest, Vol 144, Issue 24 ************************************************
_______________________________________________ Linux-PowerEdge mailing list [email protected] https://lists.us.dell.com/mailman/listinfo/linux-poweredge