Hi Nunio

These are the minimum required Ubuntu packages to make use of OMSA command line 
interface (includes Storage related commands as well) alone.
srvadmin-deng
srvadmin-hapi
srvadmin-isvc
srvadmin-nvme
srvadmin-omacore
srvadmin-omacs
srvadmin-omcommon
srvadmin-omilcore
srvadmin-ominst
srvadmin-smcommon
srvadmin-storage
srvadmin-storage-cli
srvadmin-storelib
srvadmin-storelib-sysfs
srvadmin-xmlsup

After installation of the above packages, please start the Data manager service 
using the below command.

service dataeng start

Regards

Chandra

----------------------------------------------------------------------

Message: 1
Date: Mon, 16 May 2016 14:16:18 -0400
From: Nunio Besnes
Subject: [Linux-PowerEdge] Ubuntu - Minimum OMSA install with omreport
To: [email protected]
Message-ID:

Content-Type: text/plain; charset="utf-8"

I've got a mix of servers some ubuntu 12.04, some 14.04. I'd like to use 
"omreport system alertlog" in a cron script to check hardware status and act 
upon hardware alerts (disk failure, overheating, power issues, etc.). I do not 
need a web interface and don't have the idrac configured. I've installed 
srvadmin-all and it works, but I'd rather not have stuff installed that I don't 
need. What would be the minimum I need to install for my purposes?

Nunio
-------------- next part --------------
An HTML attachment was scrubbed...
URL: 
http://lists.us.dell.com/pipermail/linux-poweredge/attachments/20160516/583f7b14/attachment-0001.html

------------------------------

_______________________________________________
Linux-PowerEdge mailing list
[email protected]
https://lists.us.dell.com/mailman/listinfo/linux-poweredge

End of Linux-PowerEdge Digest, Vol 144, Issue 24
************************************************
_______________________________________________
Linux-PowerEdge mailing list
[email protected]
https://lists.us.dell.com/mailman/listinfo/linux-poweredge

Reply via email to