Dell - Internal Use - Confidential Hi Davide, You can use OMSA ( Open Manage Server Administrator) system management tool to get slot occupancy report for the specific controller. This report will give you the bay details and physical disk slot information.
In GUI You can navigate to "Storage->select Report->view slot occupancy report". OMSA CLI COMMAND for getting slot occupancy report: omreport storage enclosure controller=0 enclosure=0:1 info=pdslotreport -------------------------------------OUTPUT--------------------------------------------------------- Details of Enclosure on Controller PERC ( controller name) ID : 0:1 Slot Count : 24 Occupied Slot Count : 12 Empty Slot Count : 12 Occupied Slots : 0,11,12,13,14,15,16,18,19,21,22,23 Empty Slots : 1,2,3,4,5,6,7,8,9,10,17,20 -------------------------------------------------------------------------------------------------------------- Please let us know if you need any more information about this. Regards, Deepesh C.P -----Original Message----- From: linux-poweredge-bounces-Lists On Behalf Of linux-poweredge-request-Lists Sent: Monday, January 23, 2017 11:30 PM To: linux-poweredge-Lists <[email protected]> Subject: Linux-PowerEdge Digest, Vol 152, Issue 28 Send Linux-PowerEdge mailing list submissions to [email protected] To subscribe or unsubscribe via the World Wide Web, visit https://lists.us.dell.com/mailman/listinfo/linux-poweredge or, via email, send a message with subject or body 'help' to [email protected] You can reach the person managing the list at [email protected] When replying, please edit your Subject line so it is more specific than "Re: Contents of Linux-PowerEdge digest..." Today's Topics: 1. Re: R720XD and X540-AT2 NICs overheating (Tuc at Beach House) 2. Enumerate total disk bays (Davide Ferrari) ---------------------------------------------------------------------- Message: 1 Date: Mon, 23 Jan 2017 10:55:38 -0500 From: Tuc at Beach House <[email protected]> Subject: Re: [Linux-PowerEdge] R720XD and X540-AT2 NICs overheating To: Russell Kackley <[email protected]> Cc: "[email protected]" <[email protected]> Message-ID: <cam-0slx7-jzr_q9qt-dzm9rehlem+rhmxholfb5jr0ztp6x...@mail.gmail.com> Content-Type: text/plain; charset="utf-8" Hi, No, I haven't. Personally, I think the idea of burning out my fans to fix a poor design really sucks. I'm going to try the "Update BIOS/NIC" first, see how that does for me. If not, we've been setting via racadm if len(thermal_profile) and thermal_profile != 'maximum performance': set_value('system.thermalsettings.ThermalProfile', '1') if len(base_algorithm) and base_algorithm != 'maximum performance': set_value('system.thermalsettings.BaseAlgorithm', '1') if len(fan_speed_offset) and fan_speed_offset != 'low fan speed': set_value('system.thermalsettings.FanSpeedOffset', '0') You're saying that according to https://en.community.dell.com/techcenter/extras/m/white_papers/20441060/download set system.thermalsettings.FanSpeedOffset to 2, then if that doesn't work 1, and as a last resort (And don't want to be able to hear anything in the datacenter besides fans) to 3? Thanks, Tuc On Fri, Jan 20, 2017 at 4:18 PM, Russell Kackley <[email protected]> wrote: > Hi Tuc, > > We had what sounds like a similar problem to yours. Fortunately, the > change to the fan speed offset solved the problem for us. Here are the > details: > > We have 3 PE R720 servers that were purchased in mid-2013. All of them > have Intel X540/2P I350 rNDC 10 Gb/s NIC's in them. I'm guessing that > is similar to what you have in your R720XD. Two of the servers have > worked flawlessly for the past three years. However, one of them, even > from the early days of use, would intermittently report the following error: > > The system board NDC PG voltage is outside of range. > > That would cause a reboot event, which was obviously a serious problem. > The server was under warranty and the technician tried replaced both > the NIC and the motherboard. We still got the same error and reboot problem. > Eventually, the issue got elevated to a L3 technician at Dell and they > advised us to set the "Fan speed offset" to the "Low Fan Speed Offset"" > setting. We made that change to the problem server and its performance > has been perfectly fine since then. I'm guessing that the fan speed > change solved the NIC overheating problem. > > I'm sorry to hear that it doesn't seem to have solved your problem. I > think that the iDRAC Settings-Thermal GUI offers the "High Fan Speed > Offset", which runs the fans faster than the "Low Fan Speed Offset" > setting. Did you try the "High Fan Speed Offset" setting to see if > that corrects the problem? > > On Fri, Jan 20, 2017 at 6:47 AM, Tuc at Beach House > <[email protected]> > wrote: > >> Hi, >> >> We have an older R720XD (Ship date: September 07, 2012) that has >> X540-AT2 NICs (10G). The system seems to shut down the NICS for overheating. >> Apparently, Dell told them just to change the "Thermal Profile" to >> Max, and the "Fan Speed Offset" to low. That worked for a while, but >> now its happening again. The unit isn't under warranty, so I can't >> call Dell anymore. >> >> Has anyone else found a way around this. Its a hadoop node that just >> "disappears" on us and causes problems. >> >> Thanks, Tuc >> >> _______________________________________________ >> Linux-PowerEdge mailing list >> [email protected] >> https://lists.us.dell.com/mailman/listinfo/linux-poweredge >> >> > > > -- > Russell Kackley > Subaru Telescope > Hilo, Hawaii > > -------------- next part -------------- An HTML attachment was scrubbed... URL: http://lists.us.dell.com/pipermail/linux-poweredge/attachments/20170123/0cf35384/attachment-0001.html ------------------------------ Message: 2 Date: Mon, 23 Jan 2017 17:23:33 +0100 From: Davide Ferrari <[email protected]> Subject: [Linux-PowerEdge] Enumerate total disk bays To: [email protected] Message-ID: <capu8gx6owgc2jz3rytftkakkjm8cnlq-ketdryk_swgmff2...@mail.gmail.com> Content-Type: text/plain; charset="utf-8" Hello is there a way to enumerate the physical disk bays in a PowerEdge server, both used and empty? -- Davide Ferrari Senior Systems Engineer -------------- next part -------------- An HTML attachment was scrubbed... URL: http://lists.us.dell.com/pipermail/linux-poweredge/attachments/20170123/b357a5c3/attachment-0001.html ------------------------------ _______________________________________________ Linux-PowerEdge mailing list [email protected] https://lists.us.dell.com/mailman/listinfo/linux-poweredge End of Linux-PowerEdge Digest, Vol 152, Issue 28 ************************************************ _______________________________________________ Linux-PowerEdge mailing list [email protected] https://lists.us.dell.com/mailman/listinfo/linux-poweredge