Hi Xavier.

I'm trying to understand exactly what you did...

I'm guessing here the scenario, please correct me if I'm wrong:
You've tried to work with RoCE over ConnectX-3 using RC QP.
You were able to send messages up to 1024 (including this value) and it failed.

You've to execute the same test over ConnectX-2 SDR and everything passed.

I suspect that the problem is with the MTU, since in IB the MTU values
are different than in Ethernet (the "typical" value in IB is 2/4KB and
in Ethernet it is 1500 bytes).

Can you try to set the path MTU of the QPs (when calling
ibv_modify_qp) to 1K MTU?
Maybe this will solve your problem ...

Please keep me posted
Dotan
--
To unsubscribe from this list: send the line "unsubscribe linux-rdma" in
the body of a message to [email protected]
More majordomo info at  http://vger.kernel.org/majordomo-info.html