Greetings all,

This is technically not a Linux specific question, more along the 
lines of Ultra SCSI.  But I'm hoping someone will have a quick 
answer for me anyway.

I've got a Symbios 8751SP SCSI controller (53C825 based) - it's
Ultra-Wide.  I've got the following setup internally:

  + Controller (ID 7)
  +--- unused connection
  +--- unused connection
  +--- HP 1.1 GB HD (Fast - Narrow - ID 1)
  +--- Sony CDU-76S 4x CD-ROM (Slow - Narrow - ID 6)
  +--- unused connection
  +--- Quantum Viking 4.5 GB HD (Ultra - Wide - ID 0)
       Termination Enabled - Term Power enabled

For the Narrow devices, I have 68-50 pin adaptors.

Now, this all boots and runs just fine.  I have the Quantum running
at 40 MB/s - the HP is at 10 MB/s and the Sony is at 5 MB/s - all as
expected.  The HP does NOT have Term Enabled, and I've removed the
resistor blocks from the Sony (I assume that's correct, as I don't
have and can't find online any docs for the Sony). 

Now, however, I'm trying to connect a Jaz 2GB drive (Ultra - Narrow -
ID3) to the external connector, and it's giving me lots of grief.  
When I first tried this, I couldn't even get LILO to come up.  Then
I removed the narrow devices from the internal chain, and I could
boot, but loading the kernel had a number of timeouts and other
problems.  Despite that I was able to boot fully - and shutdown
right away again...

Finally, I jacked the Quantum down to 20 MB/s, (using the Symbios 
BIOS setup), things got better, and I could connect the other internal
devices.  But it's still having occasional timeout problems - say
one ever 5 to 10 minutes, depending on how heavily I use thing. 
And they are all still on ID 0 (the end of the chain). This causes 
the controller to reset the bus, which basically lock severything 
up for 5-10 seconds.  Needless to say, I'm not very comfortable with
this. 

Now, the external cable is fairly high quality - cablestogo.com, 
part # 08252 - SCSI MD68M - MD50M.  It fits nice and tight.  The
internal cable also seems of reasonable quality; it's a 7 device 
cable I got from oscarno1.com.  The 68-50 pin adaptors also seem
reasonable quality - oscarno1.com again.  I have the Jaz setup 
with Term enabled (rather than their Auto setting).

The internal cable is probably about 1 meter.  The external cable 
is about 3 feet.   Could the length of the chain be causing me 
problems?  I've seen references that indicate that the total SCSI
length should be less than 1.5M for Ultra - I guess I'm exceeding 
that slightly.  Would moving all the internal devices closer to 
the controller work.  Are there any issues with the dangling cable 
out there?  Should I get a smaller (4-device) cable?

I've tried all kinds of things to try and get this to work, 
but I haven't had any luck.  I really want to get things working
reliably at their correct speeds.  Any suggestions would be 
greatly appreciated.  I'm already toying with replacing the 
CD-ROM, since it's the only slow device, but I don't think that 
will help much. 

Thanks,
Pete

-
To unsubscribe from this list: send the line "unsubscribe linux-scsi" in
the body of a message to [EMAIL PROTECTED]

Reply via email to