On Wed, May 09, 2001 at 01:30:02PM +0200, Wolfgang Grandegger wrote:

> On a Sitecom device this is a possible scenario. I only have an
> "original" MCT U-232 and there I have seen the Win98 baudrate settings
> with SniffUSB. Furthermore I tested it with a null-modem cable to
> my PC running minicom/zmodem transfers and the throughput increased 
> with the baudrate.

When using minicom this is equivalent to using a fixed baudrate device,
so even being able to send some characters from one PC to the other
means that the baudrate is correct.

> > BTW: Did you see my other patch concerning the maximum packet
> > size for the output endpoint of this same device ?
> 
> Yes I have realized it. I have the impression that your device
> is not equivalent to mine.

Very possible. But with the two modifications I made the device 
seems to work very reliably (made a PPP connection over the null
modem cable and used it for over 6 hours, transfering tens of
megabytes, etc).

Stelian.
-- 
Stelian Pop <[EMAIL PROTECTED]>
|------------- Ingénieur Informatique Libre --------------|
| Alcôve - http://www.alcove.com - Tel: +33 1 49 22 68 00 |
|----------- Alcôve, l'informatique est libre ------------|

_______________________________________________
[EMAIL PROTECTED]
To unsubscribe, use the last form field at:
http://lists.sourceforge.net/lists/listinfo/linux-usb-devel

Reply via email to