On Tuesday 07 September 2004 10:59 am, Alan Stern wrote:
> On Mon, 6 Sep 2004, Kyle Harris wrote:
> > Hi,
> >
> > My HC (Cypress CY7C67300) has 2 independent serial engines (SIEs) that
> > each control 2 downstream ports. I currently register each SIE as
> > standalone HCDs, each with 2 ports. The first port for each SIE works
> > fine. But. I'm not sure how to insure both ports of the SIE are
> > registered. Should they each be a virtual root hub? What is the correct
> > way to do this.
>
> Each SIE should be a root hub, not each port.  To insure that all the
> ports are registered, all you need to do is have your hub_control()
> routine respond to Get-Hub-Descriptor requests with the correct number of
> ports in the third byte of the response buffer.
>

How do I determine which port a urb is destined to? I'm assuming it is in the 
urb or dev struct somewhere.

Thanks, Kyle.


-------------------------------------------------------