Georg Acher wrote:
> On Fri, Aug 18, 2000 at 01:26:32AM +0000, Charlie Flynn wrote:
> > Hi George
> >
> > I have just tried using the alternative driver uhci.o without success.
>
> That is a very strong indication that your code has some ... problems.
I managed to get it to work (using usb-uhci.o) by retransmitting the first 64-byte
packet. In otherwords if I have (say) 'X' bytes to send I send the 1st 64 bytes twice
then I can send the remaining packets as normal.
I have successfully sent upto 16384 bytes from the iPAQ to the PC using this kludge. I
will take a CATC trace with and without the kludge. It looks like some sort of timing
problem.
>
> How do you initialize the URBs?
I use the FILL_BULK_URB macro as per the Programmer's Ref Manual.
>
> > /* at this point the iPAQ receives the 64 bytes and returns a 63 byte packet */
> > return 0;
> > }
> >
> > /* call back is as simple as this - it is never called if I send <= 64 bytes. If
> > I send > 64 bytes it reports only pktlen-64*/
> > my_rx_complete(urb_t *purb)
> > {
> > printk("RXComplete Called Packet=%d",pkt_count);
> > }
>
> I assume you mean urb->actual_length?
Yes. The point I was trying to make was the callback function was never being called if
I sent less or equal to 64 bytes.
---------------------------------------------------------------------
To unsubscribe, e-mail: [EMAIL PROTECTED]