On Fri, Mar 14, 2008 at 05:47:38PM -0600, Héctor Hugo Avilés Arriaga wrote: > Thanks for the previous tip.
I have to second that. This test app finally shows up the different settings. I have dumped my settings of the cam both after a cold start with the defaults and after letting windows onto the cam. here is the diff: [EMAIL PROTECTED]:~$ diff -u logi9k-linsettings logi9k-winsettings --- logi9k-linsettings 2008-03-14 11:30:28.000000000 +0100 +++ logi9k-winsettings 2008-03-14 11:30:12.000000000 +0100 -control 0x00980918 Power Line Frequency min 0 max 2 step 1 default 2 current 2. +control 0x00980918 Power Line Frequency min 0 max 2 step 1 default 2 current 1. 0: Disabled 1: 50 Hz 2: 60 Hz -control 0x0098091a White Balance Temperature min 0 max 10000 step 10 default 4000 current 4000. +control 0x0098091a White Balance Temperature min 0 max 10000 step 10 default 4000 current 7322. -control 0x009a0902 Exposure (Absolute) min 1 max 10000 step 1 default 166 current 166. -control 0x009a0903 Exposure, Auto Priority min 1 max 10000 step 1 default 166 current 1. +control 0x009a0902 Exposure (Absolute) min 1 max 10000 step 1 default 166 current 338. +control 0x009a0903 Exposure, Auto Priority min 1 max 10000 step 1 default 166 current 0. So it boils down to Power Line Frequency, White balance and Exposure. I tried changing these settings with luvcview, but got only errors. can this test.c be enhanced to be able to set those parameters? thanks Philipp -- The more I learn about people, the more I like my dog! _______________________________________________ Linux-uvc-devel mailing list [email protected] https://lists.berlios.de/mailman/listinfo/linux-uvc-devel