On Mon, 11 Jun 2018 at 12:48, Arend van Spriel
<[email protected]> wrote:
> On 5/30/2018 1:52 PM, Rafał Miłecki wrote:
> > I'm providing extra version info of tested firmware images as requested
> > by Arend in another e-mail thread.
>
> Looking into our firmware repo it there are two flags, ie. WL_MONITOR
> and WL_RADIOTAP. It seems both are set for firmware containing -stamon-
> feature. Your list below confirms that. I still plan to add indication
> for WL_RADIOTAP in the "cap" iovar, but a stamon feature check could be
> used for older firmwares.

The problem is that there isn't a direct mapping between what's
visible with the "tail" command and what firmware returns for the
"cap" iovar. Just to be sure I bumped #define MAX_CAPS_BUFFER_SIZE to
1024. Firmware that has "stamon" when checked with "tail" command
doesn't report "stamon" over "cap" iovar. So I can't detect if
firmware was compiled with WL_MONITOR and WL_RADIOTAP using "cap"
iovar.