if you have two non coherent ht device in the same ht chain. ....you need to assign different unit id value to it.
YH On Tue, 15 Mar 2005 14:50:48 -0500, [EMAIL PROTECTED] <[EMAIL PROTECTED]> wrote: > > > Hello, > > > > In the file /freebios2/src/northbridge/amd/amdk8/incoherent_ht.c, they are > trying to â > > > > /* Spin through the devices and collapse any previous > > * hypertransport enumeration. > > */ > > > > Essentially, the ht_collapse_previous_enumeration() is writing to bits 20:16 > of register 0x44 on the HT device, a.k.a. the Capabilities Register. What > happens is that the devices before this start with HT as 0.0.0 and so on. > After this, HT is 1.1.0. Why does LB want to do this? > > > > I'm not saying this is wrong or right, I just want to understand. I have a > PheonixBIOS for this same board I am working with and it doesn't change the > BASE_UNIT_ID and works fine. > > > > Anyone want to elaborate on this? > > > > > > Cheers, > Peter Van Echaute > > Email: [EMAIL PROTECTED] > > _______________________________________________ Linuxbios mailing list Linuxbios@clustermatic.org http://www.clustermatic.org/mailman/listinfo/linuxbios