**************************************** * LUG meet on 12 Jan. 2003 @ VJTI ****************************************
Hemang C. Ajmera writes: [snip]
Waiting for reader process to fill input buffer ... input buffer ready.My writer was giving a similar error when the media was bad. I have a
Performing OPC...
cdrecord: Input/output error. send opc: scsi sendcmd: no error
CDB: 54 01 00 00 00 00 00 00 00 00
status: 0x2 (CHECK CONDITION)
Sense Bytes: 70 00 03 00 00 00 00 0A 00 00 00 00 73 03 00 00
Sense Key: 0x3 Medium Error, Segment 0
Sense Code: 0x73 Qual 0x03 (power calibration area error) Fru 0x0
Sense flags: Blk 0 (not valid) cmd finished after 10.797s timeout 200s
cdrecord: Resource temporarily unavailable. OPC failed.
samsung writer as well. Did you try changing the media? Also Samsungs writer
does not work with certain media (eg Imation). I still have not been able
to figure out why.
****************
Vinayak Hegde
APGDST Student
NCST-JUHU
****************
--
_______________________________________________
http://mm.ilug-bom.org.in/mailman/listinfo/linuxers