On Wed, Jun 07, 2017 at 02:46:39PM +0000, Rodney Greenstreet wrote:
> Based on these clauses, it’s clear that each port maintains its own
> sync interval setting and needs to maintain its own sync interval
> timer. It’s also clear that when the slave port of a TAB receives a
> sync event, that message is not immediately sent out on downstream
> ports. Rather, the configured sync interval for a given port must be
> adhered to.

Consider clause B.2.2.  There the residence time is limited to 10
milliseconds at maximum.  Using an internal timer to forward the Sync
message would violate this requirement.

Thanks,
Richard

------------------------------------------------------------------------------
Check out the vibrant tech community on one of the world's most
engaging tech sites, Slashdot.org! http://sdm.link/slashdot
_______________________________________________
Linuxptp-devel mailing list
Linuxptp-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/linuxptp-devel

Reply via email to