On Wed, Jun 07, 2017 at 04:24:52PM +0000, Rodney Greenstreet wrote: > Please read clause 10.6.2.3 ‘time-synchronization event message transmission > interval’ and clause 10.6.2.4 ‘Interval for providing synchronization > information > by ClockMaster entity’. The last clause makes it very clear that the > ClockMaster entity > shall set it’s clockMasterLogSyncInterval to a “value is less than or equal > to the > smallest currentLogSyncInterval (see 10.6.2.3) value for all the ports of the > time-aware > system.” > > This clause makes it very clear that each port will send it’s Sync event > based on it’s > configured currentLogSyncInterval.
Only when acting as GM. Thanks, Richard ------------------------------------------------------------------------------ Check out the vibrant tech community on one of the world's most engaging tech sites, Slashdot.org! http://sdm.link/slashdot _______________________________________________ Linuxptp-devel mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/linuxptp-devel