On Tue, Aug 14, 2018 at 02:56:44PM +0200, Michael Walle wrote: > AVnu specifies a measurement method to remotely measure the clock > quality. Basically, this method sends Sync and/or Follow-up messages on > a slave towards the master, which can capture them and measure the > quality.
We already have this exact functionality with NSM support. > The AVnu specification [1] introduces three parameters: ... > [1] > https://avnu.org/wp-content/uploads/2014/05/Avnu-Testability-802.1AS-Recovered-Clock-Quality-Measurement-1.0_Approved-for-Public-Release.pdf That looks like abandonware. I'll need much stronger evidence that a) the above is a widely accepted protocol extension, and b) there is a real demand for the same before I even look at this series. Thanks, Richard ------------------------------------------------------------------------------ Check out the vibrant tech community on one of the world's most engaging tech sites, Slashdot.org! http://sdm.link/slashdot _______________________________________________ Linuxptp-devel mailing list Linuxptp-devel@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/linuxptp-devel