On Tue, Aug 14, 2018 at 02:56:44PM +0200, Michael Walle wrote:
> AVnu specifies a measurement method to remotely measure the clock
> quality. Basically, this method sends Sync and/or Follow-up messages on
> a slave towards the master, which can capture them and measure the
> quality.

We already have this exact functionality with NSM support.
 
> The AVnu specification [1] introduces three parameters:
...
> [1] 
> https://avnu.org/wp-content/uploads/2014/05/Avnu-Testability-802.1AS-Recovered-Clock-Quality-Measurement-1.0_Approved-for-Public-Release.pdf

That looks like abandonware.  I'll need much stronger evidence that

   a) the above is a widely accepted protocol extension, and
   b) there is a real demand for the same

before I even look at this series.

Thanks,
Richard

------------------------------------------------------------------------------