Today I finally  got back  to work on the V240  which  repeatedly lost its  
mddb's
Tom's suggestion of putting only one  mddb on each disk worked well !
This  server  had disks :  2 of: Fujitsu_MAT3147N   and 2 of: Fujitsu_MAT3073N  
installed.
I think we can say with some certanity  that they  do trigger a variant  of BUG 
 6244431

    Thank you Tom   for this  advice.

    //Lars
This message posted from opensolaris.org

Reply via email to