Hi, 

  I experienced  a  disasterous lvm  installation failure today.  On solaris 9 
9/05 SPARC V240 
  with 2 * 73 Gb disk  and 2 * 146 GB disk
  By placing  the metadb  in the last  128 MB on the " new"  146 GB  disks  on 
a  SUNFIRE V240, 
  and re-booting the server .   When LVM  tries to activate  itself on powerup 
, all metadb  copies  vanish  into the great bit-bucket  never to be seen 
again.  

   I thought about this for awhile ...   Then I  reinstalled the metadbs again  
on only my two 
  73 GB disk.   this time lvm behaved normally. 

   Question :  is LVM  vunerable if  metadb's  are placed  after the 137 GB 
boundary on a disk 
   
    I will try  next week to place the metadbs  first on the 146 GB disk and 
see if they are stable  in that configuration.
 Regards
 //Lars
This message posted from opensolaris.org