On November 8, 2026 11:31:19 PM PST, "John R. Hogerhuis" <[email protected]> wrote: >On Sun, Nov 8, 2026 at 11:16 PM Daniel <[email protected]> wrote: > >> "John R. Hogerhuis" <[email protected]> writes: >> >> > Can anyone explain to me "cycles" versus "states" in regard to the >> 8085 >> > and the model 100? >> > Should I be able to translate clock speed and instruction cycles >> > directly to time? >> > How accurate are the rtc and cpu crystals in the M100? >> > Are there waits when accessing RAM that might change timing? >> > I am doing some analysis with timing loops and it seems to indicate >> the >> > cpu is actually running at 2.3235mhz. But nominalé is 2.4576mhz right >> > (after /2)? >> > -- John. >> >> instruct timing is measured in T-states right? each equals a CPU clock >> period. You should be able to calculate execution time directly at >> 2.4576. Though the m100 generates interrupts at 256Hz for housekeeping, >> it might account for the apparent slowdown. Could you try running the >> timing >> loop with interrupts temporarily disabled? Maaybe youd see the expected >> clock speed. >> >> >Running test under disabled interrupts, yes. > >Thanks, > >-- John.
How did it turn out? daniel sysop | air & wave bbs finger | [email protected]