This message (and attachments) is subject to restrictions and a disclaimer. 
Please refer to http://www.unisa.ac.za/disclaimer for full details.
________________________________

Thanks for the input and clarification.

Robin

From: [email protected] 
[mailto:[email protected]] On Behalf Of Ray Zimmerman
Sent: 06 October 2011 08:46 PM
To: MATPOWER discussion forum
Subject: Re: LMP for Reserves

Since the formulation for the OPF with reserves uses fixed zonal reserve 
constraints, the prices are defined in terms of these zonal constraints. They 
are not strictly nodal prices. The fact that the zones can overlap makes it 
even trickier. The reserve price computed by MATPOWER for a given generator is 
the sum of the shadow prices on the zonal constraints for the zones to which 
that generator belongs.

I suppose you could assign the load buses to the zones as well, and simply 
*define* the reserve price at the load buses the same way. But it would be just 
that, a definition.


--
Ray Zimmerman
Senior Research Associate
419A Warren Hall, Cornell University, Ithaca, NY 14853
phone: (607) 255-9645





On Oct 6, 2011, at 8:31 AM, Naidoo, Robin wrote:


This message (and attachments) is subject to restrictions and a disclaimer. 
Please refer to http://www.unisa.ac.za/disclaimer for full details.
________________________________

Good Day,

When performing an opf with reserves Matpower gives the LMP for reserves at the 
generator buses. In the case where there is no congestion, the price will be 
uniform at all buses.  In the case where there is congestion on the network , 
the prices will not be the same at all the buses. I need some suggestion on how 
to obtain the prices at the non generator buses.

Thanks
Robin


Reply via email to