2015-07-24 23:24 GMT+08:00 Ray Zimmerman <[email protected]>:

> There is no problem with using direct specification to supply a vector
> rhat, with different shift for each nodal voltage. Simply define N so that
> r is the vector of bus voltages, then rhat can be the corresponding shifts.
>
>     Ray
>
>
> > On Jul 24, 2015, at 11:06 AM, 陈春宇 <[email protected]> wrote:
> >
> > Hi everyone,
> >
> > I referred to Section 7.1 Direct Specification and 7.2 Callback
> Functions and have a problem regarding user-defined cost function. In my
> case, I doesn't need new variables, simply a set of nodal voltage. And I
> want to regulate them as close as to a set of values(each nodal volatge
> corresponds to different value). In Direct Specification method, rhat is
> used  as the shift for all the variables. But I need different shifts. Is
> there some way I can use or should I use Callback Functions? Thanks very
> much!
> >
> > Best Regards
>
>
>
>