Hi guys,

I’m running most_ex5_mpopf.m and try to get to a situation where load shedding 
is necessary.

For that I try to increase the load such that it will be higher than max 
generator capacity. I've tried that using: 
1. Increase profile(2).values to very high values.
2. Decrease mpc values: mpc.gen(4, [PG PMAX]) = -2000 (450 by default).

This doesn’t help and I always seem to get -540 MW in generator 4 (the 
dispatchable load). Where does this number come from? Is it intentional?
I would also appreciate if someone can give a brief overview of what is the 
relation between the profiles of most and loads of the mpc, and why does the 
MILP objective always outputs a number that contains the full load shedding 
penalty. 

Thanks,
Gal

Reply via email to