Dear Ray,
In runopf_w_res() , the zonal requirement is fixed, but I want it to be 
flexible, how can I do this ?
Thanks.








At 2020-01-03 01:36:43, "Ray Daniel Zimmerman" <[email protected]> wrote:

Hi Yang,


It’s not clear whether you simply want to use the fixed reserves extension (see 
Section 7.6.1 in the MATPOWER User’s Manual) or you want to implement your own 
OPF extension. In the first case you can simply use runopf_w_res(). In the 
second, please see Chapter 7 and the code for the various extensions described 
in Section 7.6.


   Ray




On Dec 25, 2019, at 8:11 PM, Yang <[email protected]> wrote:


Dear sir,
I want to do the extensible OPF, and I read paper MATPOWER’s Extensible Optimal 
Power Flow Architecture.
The objective function is min f(x)+fu(x,z),and fu=sum(ci*ri), following the 
code:
Ar = [I I];
om = add_vars(om, 'R', ng, [], Rmin, Rmax);
om = add_constraints(om, 'Pg_plus_R', Ar, [], Pmax, {'Pg', 'R'});
om = add_constraints(om, 'Rreq', Az, Rreq, [], {'R'});
om = add_costs(om, 'Rcost', struct('N',I,'Cw',Rcost), {'R'});


I add these into .m file, as for add_vars if I should change [], Rmin, Rmax 
into data I need, and do the same with other codes.
I don't know if it's right.
Best regards.


Yang.





 



Reply via email to