NUR40109 8 13 IV #1 Start Date:
[EMAIL PROTECTED]"NUR40109"]
NUR40560 9 8 If IV site is > 72 hours old,
NUR40566 10 8 is there a doctor's order to
NUR40570 11 9 continue using current site:
IFE=IF{%Z.date.sub(@.today,[ANS,"NUR40109B"]|0)>2
IFE= @W.return("If peripheral IV, change IV/tubing")},1
--------------------------------------------------------
Other date attributes:
Attribute to have a second date query default to x number of days before
the first date query
This attribute would allow a site to have their second date query on a
CDS default to X number of days before the response to the first date
query.
Example: Category: CARD
Procedure: EKG
CDS with two date queries added to the Procedure
Queries: DATE 1
DATE 2
Attributes: DATE 1: FCL1=%Z.date.in(@.response)^/DATE
DATE 2: DFT=%Z.date.add(/DATE,0-3) OR /DATE,3 to add 3days
to the date....
Enter Orders in OE:
CARD EKG
Date 1: 09/25/00
Date 2: 09/22/00 (defaults in)
----------------------------------------------------------------------
DATES
Attribute for date query limitations.
In order to limit the number of days a user can enter for a Date type
query enter the following attribute:
FCL1=%Z.date.sub(@.today,%Z.date.in(@.response))>6
[EMAIL PROTECTED]("This date is not acceptable")
The Message can be altered to whatever is necessary, for example:
[EMAIL PROTECTED]("Date cannot be more than 6 days prior to today")
The number of days the restriction in which the error message will
display can also be altered, example:
FCL1=%Z.date.sub(@.today,%Z.date.in(@.response))>10
With this attribute a user cannot return through the date field until an
appropriate date is entered.
-------------------------------------------------------------
IFE=IF{%Z.date.sub(@.today,[ANS,"QUERY"]|0)>365&([ANS,"QUERY"]|0)
@W.return("Time to enter
a new consent")},1
Is it possible to calculate the number of days between today and a date
in a customer defined field?
I have a CDS date field "CONDATE" that is entered when consent is
obtained. We would like to be reminded with a message when a year or
more has passed (TODAY - CONDATE > 365 DAYS) so that we can obtain
another consent.
-------------------------------------------------------------------
Attribute for date query limitations.
In order to limit the number of days a user can enter for a Date type
query enter the following attribute:
FCL1=%Z.date.sub(@.today,%Z.date.in(@.response))>6
[EMAIL PROTECTED]("This date is not acceptable")
The Message can be altered to whatever is necessary, for example:
[EMAIL PROTECTED]("Date cannot be more than 6 days prior to today")
The number of days the restriction in which the error message will
display can also be altered, example:
FCL1=%Z.date.sub(@.today,%Z.date.in(@.response))>10
With this attribute a user cannot return through the date field until an
appropriate date is entered.
-----------------------------------------------------------------
Bill Mullins RN
Williamson Medical Center
2021 Carothers Road
Franklin,Tn 37067
615-435-5630
-----Original Message-----
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of Stigen Kenneth
Sent: Wednesday, June 07, 2006 11:53 AM
To: [email protected]
Subject: [MEDITECH-L] Attribute Help - Alert message to change IV site
All messages should be posted in plain text. HTML will be converted to
attachments. The meditech-l web site is MTUsers.com
======================================
Greetings,
Forgive me I am new at attributes and could use some expert "L" advice.
I have built a CDS to monitor IV sites which defaults a date that the IV
was inserted (view only). I am looking for an attribute that will alert
the user when a peripheral IV needs to be changed i.e., 3 days.
I have looked on the archive L list but have not found something that
will work yet(or that I know how to use,lol). I have a START/DC IV CDS
that pulls to this screen. "Date of Dressing" is the first field curser
stops at. So what I need is, if type is "PIV" and the "Date Inserted"
was over 3 days, user gets an alert "Consider Changing PIV Site".
IV SITE MONITOR
View only fields: Entry Fields:
----------------- ----------------
IV Catheter Type? (PIV,ART,CL) Date of Dressing?
IV Site Location? Dressing Type?
Central Line Type? CL Still Needed?
Date Inserted? IV Site WDP?
Thanks in advance!!!
Ken
Ken Stigen, RN, BSN
Nursing Informatics
Capital Medical Center
3900 Capital Mall Drive S.W.
Olympia, WA 98502
(360) 704-4722
_______________________________________________
meditech-l mailing list
[email protected]
http://mtusers.com/mailman/listinfo/meditech-l
**********************************************************************
This email and any files transmitted with it are confidential and
intended solely for the use of the individual or entity to whom they
are addressed.
This footnote also confirms that this email message has been swept by Sophos
and MIMEsweeper for the presence of computer viruses.
**********************************************************************
_______________________________________________
meditech-l mailing list
[email protected]
http://mtusers.com/mailman/listinfo/meditech-l