Donna,
What type is your query? If it is a Blood Pressure Type, you need to
identify which piece (0 or 1). Systolic is piece 0; Diastolic is piece
1.
The following checks Systolic >220 and Diastolic >120;
FCL1=IF{%Z.age.in.years(@p.ADM.PAT.birthdate,@.today)>15&
FCL1=((@.response#"0/">220)!(@.response#"1/">120))
FCL1= [EMAIL PROTECTED]("Abnormally HIGH BP. Are you sure?")="Y" "";1}}
FCL1A=1
If your BP fields are two separate queries, change the "" at the end to
1:
[EMAIL PROTECTED]>300 @W.err("Check value just entered");1}
[EMAIL PROTECTED]<40 @W.err("Check value just entered");1}
Brian
-----Original Message-----
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of Ring, Donna -
Clinical Systems Resource Nurse Specialtist
Sent: Wednesday, June 07, 2006 7:56 AM
To: [email protected]
Subject: [MEDITECH-L] Magic-5.5-NUR range question
All messages should be posted in plain text. HTML will be converted to
attachments. The meditech-l web site is MTUsers.com
======================================
We can't get our diastolic range to work. Here is the attribute-can
anyone help me? Thank you.
[EMAIL PROTECTED]>300 @W.err("Check value just entered");""}
[EMAIL PROTECTED]<40 @W.err("Check value just entered");""}
CONFIDENTIALITY NOTICE: This e-mail transmission message, together with
any other documents or attachments, is intended only for the use of the
individual or entity to which it is addressed and may contain personal
information that is subject to confidential privacy regulations such as
the Health Insurance Portability and Accountability Act of 1996 (HIPAA).
The authorized recipient of this information is STRICTLY PROHIBITED from
disclosing this information to any other party unless required to do so
by law or regulation and is required to destroy the information after
its stated need has been fulfilled. If you are not the intended
recipient, you are hereby notified that any disclosure, dissemination,
saving, printing, copying, or action taken in reliance on the contents
of these documents of this message or any attachment, is strictly
prohibited. Please notify the original sender (only) immediately by
telephone or by reply e-mail and delete this message along with any
attachments, from your computer. Thank you.
_______________________________________________
meditech-l mailing list
[email protected] http://mtusers.com/mailman/listinfo/meditech-l
_______________________________________________
meditech-l mailing list
[email protected]
http://mtusers.com/mailman/listinfo/meditech-l